Friday, May 21, 2021

ANALOG CAPACITANCE METER

       ANALOG CAPACITANCE  METER 

hello  friends  today I am gonna  telling  you  about  some  easy  and valuable  electronics projects for  school and  college  practical 

The principle of operation of this meter is based on pulse- width modulation.  Larger the capacitance, higher is the pulse width and vice - versa.  The meter given here has one oscillator and two one - shot generators (OSG) built around RC components.  An OSG is triggered by a free - running oscillator built around IC NE555 (C1) The pulse - width of the OSG is determined by the capacitor under measurement (Cx).  By passing the pulses from the OSG through a linear ammeter it is possible to measure its duty cycle.  In other words, the deflection of the ammeter can be made equal to the duty cycle, which here becomes proportional to the value of the capacitor Cx due to linear property of the OSG time period.

Fig.  1 shows the circuit diagram of analogue capacitance meter.  The OSG comprises timing resistors (R4) through Ro) and capacitor Cx, whose voltage is sampled by CMOS gate NI.  Cx is discharged through transistor 13 connected in parallel.  Cx is connected to pin 2 of gate N1 The voltage at pin 2 of gate N1 is used as the reference voltage to which Cx has to charge.  Once this voltage is reached the sampling gate output makes the transistion from high to low state, indicating the completion of the charging time.  Charging time (on - time) of capacitor Cx is given by:

Fig1; circuit diagram

Here, V. is supply voltage and V is the threshold input voltage of gate N1.  R = R4 through Ro and C = Cx.  Due to this linearity of the RC circuit, a capacitor with twice the value would take twice the time.  Thus the OSG pulse - width and hence the duty cycle of the output waveform, becomes pro portional to the value of the capacitor due to stray capacitance of connecting wires the OSG does not produce a zero pulse without capacitor to eliminate this, a similar auxiliary OSG, comprising presets VR1 through VR3 and a capacitor C3 is used.  The presets VR1 through VR3 are adjusted such that for each range the meter gives zero indication when capacitor cx is not connected with these adjustments the meter is ready for use 

The oscillator built around IC1 should be configured such that is on time period (To) slightly  exceeds the OSG on - time period () with the full range capacitor value and off - time period (Tom) occurs just before complete discharge of capacitor.  This becomes very important for capacitors having large capacitances

The calibration of the ammeter is easy it suitable reference capacitor is available.  It is recommended to permanently include a reference capacitor say, 100nF With a reference capacitor connected, you can easily set the calibration resistance using preset VR3.  to obtain a full - scale deflection This would finish the calibration for other ranges as well.  The capacitance of cx is given by the following expression

 Here, (Vg2)  and ( Vg1) are the output gate voltages of N4 and N2, respectively . Nd is the total number of divisions on the ammeter scale, R., and R = VR3 are the meter and series calibration resistances, and is the full-scale deflection current of the meter the range of the instrument can be further extended by including lower  valued range resistances (1k gives 0-100nF and 100Ω gives 0 - luf) We have used a basic instrument to keep the diagram as simple as possible 

Since NE555 cannot supply the required current providing a con The stand voltage, additional driver stage of transistors T1 (2N3904) and T2 (N3906) have been included.  The pulsed drive automatically cuts - off the supply during off - cycle, enabling a proper discharge of Cx, which is important to get the right value of the capacitor otherwise partially charged capacitor will be subjected to the next charge cycle and indicating a lower value An indicative timing diagram (not to scale) is given in Fig 2

Fig2; waveforms diagram

The circuit takes some time to stabilize thermally and is  More suitable as a lab instrument It is recommended to include a lower valued variable resistance in series  with the preset controlling the current through the meter This will allow easy frequent calibration of the instrument 

Assemble the circuit on a general - purpose PCB in a suitable  enclosure Approximately 63.5cm (25 - inch) long test leads with crocodile clips are used for compensating the capacitance of this capacitance can be changed according to the length of the test leads.  Fix the ammeter in the front panel.

more projects phone  detector 1,2,3,4,5,6,7,8,9,10,11,12,13,14 ,15,16,17,18,19,20

friends please LIKE  ,SHARE and FOLLOW  thanks for your support

0 comments:

Post a Comment

ELECTRONIC CALCULATOR

               ELECTRONIC CALCULATOR hello  friends  today I am gonna  telling  you  about  some  easy  and valuable  electronics projects  ...